The Fluke 1550C insulation resistance test kit lets you evaluate the trends and eliminate the doubt.
| Accuracy (± reading) | Unspecified5%20%Unspecified |
| Accuracy (± reading) | Unspecified5%20%Unspecified |
| Accuracy (± reading) | Unspecified5%20%Unspecified |
| Accuracy (± reading) | Unspecified5%20%Unspecified |
| Accuracy (± reading) | Unspecified5%20%Unspecified |
| Bar graph range | 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555) |
| Insulation test voltage accuracy | -0%, +10% at 1 mA load current |
| Induced AC mains current rejection | 2 mA maximum |
| Charging rate for capacitive load | 5 seconds per μF |
| Discharge rate for capacitive load | 1.5 s/μF |
| Accuracy | ±(20% + 2 nA) |
| Accuracy | ±(15% rdg + 0.03 μF) |
| Resolution setting | 1 minute |
| Resolution indication | 1 second |
| Voltage accuracy | ±(15% + 2 V) |
| Software specifications | FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8. |
| Display | 75 x 105 mm |
| Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
| Charger Input (AC) | 85 V to 250 V AC 50/60 Hz 20 VA |
| Dimensions | 269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in) |
| Weight | 3.7 kg (8.2 lb) |
| Temperature (operating) | -20°C to 50°C (-4°F to 122°F) |
| Temperature (storage) | -20°C to 65°C (-4°F to 149°F) |
| Humidity | 80% to 31°C decreasing linearly to 50% at 50°C |
| Altitude | 2000 m |
| Enclosure sealing | IP40 |
| Input overload protection | 1000 V AC |
| Electromagnetic compatibility | EN 61326 |
| Safety compliance | IEC 61010-1: Overvoltage category II, Pollution Degree 2.IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT IIIIEC 61557-1, IEC 61557-2 |
问:1550C/KIT的电流精度达到什么水平?
答:1550C/KIT 的电流精度为 ±(0.2% + 2)。以上为官方规格,实际供货配置与选型可让工程师按你的测试需求核对。
问:1550C/KIT的温度测量达到什么水平?
答:1550C/KIT 的温度测量为 -200.0 °C – 1090 °C -328.0 °F – 1994.0 °F 不含探头。以上为官方规格,实际供货配置与选型可让工程师按你的测试需求核对。
问:1550C/KIT主要用在什么测量场合?
答:工业维修标配,真有效值、0.05% 基本精度,内置温度/频率档,CAT III 1000V。具体是否匹配你的测试对象,可把需求发给工程师免费核对型号。
问:1550C/KIT和同系列其他型号怎么选?
答:建议先看 电流精度(±(0.2% + 2))、电流精度(±(1.0% + 2) 真有效值) 这几项,再结合你的被测信号/器件类型确认档位。不同子型号配置有差异,选型时让工程师按需求比对最稳妥。
问:1550C/KIT 是全新原装吗?货期和保修怎么算?
答:全新原装正品、正规渠道供货,序列号可送原厂查验(非翻新、非演示机);常规配置现货或 1~2 周内发货,特殊配置下单前书面确认交期;按厂家政策享受原厂保修。